Overview
Measures volumetric flow of conductive liquids and slurries in closed pipes. With no moving parts there is no wear; readings are unaffected by temperature, pressure, viscosity or density; forward and reverse flow are both measured. Used for clean water, wastewater, slurry and pulp, chemicals and pharmaceuticals, and food processing.
Features
- Dual-frequency excitation for zero-point stability; 1:100 range ratio.
- Built-in reference electrode, no grounding rings required; self-diagnostics.
- Excellent low-flow accuracy; MODBUS (optional) or HART (optional).
- Optional cooling and heating energy metering; 8-digit display with real-time clock.
Specifications
| Nominal size | DN10 to DN3000 |
|---|---|
| Flow velocity | up to 15 m/s |
| Nominal pressure | 0.6 / 1.0 / 1.6 / 4.0 MPa or other |
| Output | 4~20 mA / pulse |
| Communication | RS485 (MODBUS, optional); HART (optional) |
| Supply | AC 86~220 V or DC 24 V (optional) |
| Media temperature | -20 to 80 °C, up to 180 °C on request (limited by liner) |
| Electrode / liner | 316L electrode (HC, Hb, Ti, Ta, Pt on request); Ne, FEP, PTFE or polyurethane liner |
| Ingress protection | IP65 integral; IP67 or IP68 remote (optional) |
| Certification | CE: LVD 2006/95/EC, EMC 2004/108/EC, EN 61010-1 |
Applications
Municipal water and wastewater metering, chemical and pharmaceutical solutions, slurry, pulp, food and beverage, circulating water and energy metering.
| Model | FST900-101 |
|---|---|
| Construction | 316L electrode, Ne / FEP / PTFE / PU liner, carbon steel body |
| Certification | CE (LVD / EMC / EN 61010-1) |
Need a model recommendation?
Send medium, range, output, process connection and hazardous-area requirement for a model and configuration list.
Inquire now